1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379
380
381
382
383
384
385
386
387
388
389
390
391
392
393
394
395
396
397
398
399
400
401
402
403
404
405
406
407
408
409
410
411
412
413
414
415
416
417
418
419
420
421
422
423
424
425
426
427
428
429
430
431
432
433
434
435
436
437
438
439
440
441
442
443
444
445
446
447
448
449
450
451
452
453
454
455
456
457
458
459
460
461
462
463
464
465
466
467
468
469
470
471
472
473
474
475
476
477
478
479
480
481
482
483
484
485
486
487
488
489
490
491
492
493
494
495
496
497
498
499
500
501
502
503
504
505
506
507
508
509
510
511
512
513
514
515
516
517
518
519
520
521
522
523
524
525
526
527
528
529
530
531
532
533
534
535
536
537
538
539
540
541
542
543
544
545
546
547
548
549
550
551
552
553
554
555
556
557
558
559
560
561
562
563
564
565
566
567
568
569
570
571
572
573
574
575
576
577
578
579
580
581
582
583
584
585
586
587
588
589
590
591
592
593
594
595
596
597
598
599
600
601
602
603
604
605
606
607
608
609
610
611
612
613
614
615
616
617
618
619
620
621
622
623
624
625
626
627
628
629
630
631
632
633
634
635
636
637
638
639
640
641
642
643
644
645
646
647
648
649
650
651
652
653
654
655
656
657
658
659
660
661
662
663
664
665
666
667
668
669
670
671
672
673
674
675
676
677
678
679
680
681
682
683
684
685
686
687
688
689
690
691
692
693
694
695
696
697
698
699
700
701
702
703
704
705
706
707
708
709
710
711
712
713
714
715
716
717
718
719
720
721
722
723
724
725
726
727
728
729
730
731
732
733
734
735
736
737
738
739
740
741
742
743
|
/* Copyright (C) 1995,1996,1997,1998,1999,2000,2001, 2002, 2004, 2006,
* 2007, 2008, 2009, 2011, 2013, 2014 Free Software Foundation, Inc.
*
* This library is free software; you can redistribute it and/or
* modify it under the terms of the GNU Lesser General Public License
* as published by the Free Software Foundation; either version 3 of
* the License, or (at your option) any later version.
*
* This library is distributed in the hope that it will be useful, but
* WITHOUT ANY WARRANTY; without even the implied warranty of
* MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE. See the GNU
* Lesser General Public License for more details.
*
* You should have received a copy of the GNU Lesser General Public
* License along with this library; if not, write to the Free Software
* Foundation, Inc., 51 Franklin Street, Fifth Floor, Boston, MA
* 02110-1301 USA
*/
#ifdef HAVE_CONFIG_H
# include <config.h>
#endif
#include <fcntl.h> /* for mingw */
#include <signal.h>
#include <stdio.h>
#include <errno.h>
#ifdef HAVE_PROCESS_H
#include <process.h> /* for mingw */
#endif
#include <unistd.h>
#ifdef HAVE_SYS_TIME_H
#include <sys/time.h>
#endif
#include <full-write.h>
#include "libguile/_scm.h"
#include "libguile/async.h"
#include "libguile/eval.h"
#include "libguile/vectors.h"
#include "libguile/threads.h"
#include "libguile/validate.h"
#include "libguile/scmsigs.h"
/* SIGRETTYPE is the type that signal handlers return. See <signal.h> */
#ifdef RETSIGTYPE
# define SIGRETTYPE RETSIGTYPE
#else
# ifdef STDC_HEADERS
# define SIGRETTYPE void
# else
# define SIGRETTYPE int
# endif
#endif
/* take_signal is installed as the C signal handler whenever a Scheme
handler is set. When a signal arrives, take_signal will write a
byte into the 'signal pipe'. The 'signal delivery thread' will
read this pipe and queue the appropriate asyncs.
When Guile is built without threads, the signal handler will
install the async directly.
*/
/* Scheme vectors with information about a signal. signal_handlers
contains the handler procedure or #f, signal_handler_asyncs
contains the thunk to be marked as an async when the signal arrives
(or the cell with the thunk in a singlethreaded Guile), and
signal_handler_threads points to the thread that a signal should be
delivered to.
*/
static scm_i_pthread_mutex_t signal_handler_lock =
SCM_I_PTHREAD_MUTEX_INITIALIZER;
static SCM *signal_handlers;
static SCM signal_handler_asyncs;
static SCM signal_handler_threads;
/* The signal delivery thread. */
scm_i_thread *scm_i_signal_delivery_thread = NULL;
/* The mutex held when launching the signal delivery thread. */
static scm_i_pthread_mutex_t signal_delivery_thread_mutex =
SCM_I_PTHREAD_MUTEX_INITIALIZER;
/* saves the original C handlers, when a new handler is installed.
set to SIG_ERR if the original handler is installed. */
#ifdef HAVE_SIGACTION
static struct sigaction orig_handlers[NSIG];
#else
static SIGRETTYPE (*orig_handlers[NSIG])(int);
#endif
static SCM
close_1 (SCM proc, SCM arg)
{
/* Eval in the root module so that `lambda' has its usual meaning. */
return scm_eval (scm_list_3 (scm_sym_lambda, SCM_EOL,
scm_list_2 (proc, arg)),
scm_the_root_module ());
}
#if SCM_USE_PTHREAD_THREADS
/* On mingw there's no notion of inter-process signals, only a raise()
within the process itself which apparently invokes the registered handler
immediately. Not sure how well the following code will cope in this
case. It builds but it may not offer quite the same scheme-level
semantics as on a proper system. If you're relying on much in the way of
signal handling on mingw you probably lose anyway. */
static int signal_pipe[2];
static SIGRETTYPE
take_signal (int signum)
{
char sigbyte = signum;
full_write (signal_pipe[1], &sigbyte, 1);
#ifndef HAVE_SIGACTION
signal (signum, take_signal);
#endif
}
struct signal_pipe_data
{
char sigbyte;
ssize_t n;
int err;
};
static void*
read_signal_pipe_data (void * data)
{
struct signal_pipe_data *sdata = data;
sdata->n = read (signal_pipe[0], &sdata->sigbyte, 1);
sdata->err = errno;
return NULL;
}
static SCM
signal_delivery_thread (void *data)
{
int sig;
#if HAVE_PTHREAD_SIGMASK /* not on mingw, see notes above */
sigset_t all_sigs;
sigfillset (&all_sigs);
/* On libgc 7.1 and earlier, GC_do_blocking doesn't actually do
anything. So in that case, libgc will want to suspend the signal
delivery thread, so we need to allow it to do so by unmasking the
suspend signal. */
sigdelset (&all_sigs, GC_get_suspend_signal ());
scm_i_pthread_sigmask (SIG_SETMASK, &all_sigs, NULL);
#endif
while (1)
{
struct signal_pipe_data sigdata;
scm_without_guile (read_signal_pipe_data, &sigdata);
sig = sigdata.sigbyte;
if (sigdata.n == 1 && sig >= 0 && sig < NSIG)
{
SCM h, t;
h = SCM_SIMPLE_VECTOR_REF (signal_handler_asyncs, sig);
t = SCM_SIMPLE_VECTOR_REF (signal_handler_threads, sig);
if (scm_is_true (h))
scm_system_async_mark_for_thread (h, t);
}
else if (sigdata.n == 0)
break; /* the signal pipe was closed. */
else if (sigdata.n < 0 && sigdata.err != EINTR)
perror ("error in signal delivery thread");
}
return SCM_UNSPECIFIED; /* not reached unless all other threads exited */
}
static void
start_signal_delivery_thread (void)
{
SCM signal_thread;
scm_i_pthread_mutex_lock (&signal_delivery_thread_mutex);
if (pipe2 (signal_pipe, O_CLOEXEC) != 0)
scm_syserror (NULL);
signal_thread = scm_spawn_thread (signal_delivery_thread, NULL,
scm_handle_by_message,
"signal delivery thread");
scm_i_signal_delivery_thread = SCM_I_THREAD_DATA (signal_thread);
scm_i_pthread_mutex_unlock (&signal_delivery_thread_mutex);
}
void
scm_i_ensure_signal_delivery_thread ()
{
static scm_i_pthread_once_t once = SCM_I_PTHREAD_ONCE_INIT;
scm_i_pthread_once (&once, start_signal_delivery_thread);
}
#else /* !SCM_USE_PTHREAD_THREADS */
static SIGRETTYPE
take_signal (int signum)
{
SCM cell = SCM_SIMPLE_VECTOR_REF (signal_handler_asyncs, signum);
scm_i_thread *t = SCM_I_CURRENT_THREAD;
if (scm_is_false (SCM_CDR (cell)))
{
SCM_SETCDR (cell, t->pending_asyncs);
t->pending_asyncs = cell;
}
#ifndef HAVE_SIGACTION
signal (signum, take_signal);
#endif
}
void
scm_i_ensure_signal_delivery_thread ()
{
return;
}
#endif /* !SCM_USE_PTHREAD_THREADS */
static void
install_handler (int signum, SCM thread, SCM handler)
{
if (scm_is_false (handler))
{
SCM_SIMPLE_VECTOR_SET (*signal_handlers, signum, SCM_BOOL_F);
SCM_SIMPLE_VECTOR_SET (signal_handler_asyncs, signum, SCM_BOOL_F);
}
else
{
SCM async = close_1 (handler, scm_from_int (signum));
#if !SCM_USE_PTHREAD_THREADS
async = scm_cons (async, SCM_BOOL_F);
#endif
SCM_SIMPLE_VECTOR_SET (*signal_handlers, signum, handler);
SCM_SIMPLE_VECTOR_SET (signal_handler_asyncs, signum, async);
}
SCM_SIMPLE_VECTOR_SET (signal_handler_threads, signum, thread);
}
SCM
scm_sigaction (SCM signum, SCM handler, SCM flags)
{
return scm_sigaction_for_thread (signum, handler, flags, SCM_UNDEFINED);
}
/* user interface for installation of signal handlers. */
SCM_DEFINE (scm_sigaction_for_thread, "sigaction", 1, 3, 0,
(SCM signum, SCM handler, SCM flags, SCM thread),
"Install or report the signal handler for a specified signal.\n\n"
"@var{signum} is the signal number, which can be specified using the value\n"
"of variables such as @code{SIGINT}.\n\n"
"If @var{handler} is omitted, @code{sigaction} returns a pair: the\n"
"CAR is the current\n"
"signal hander, which will be either an integer with the value @code{SIG_DFL}\n"
"(default action) or @code{SIG_IGN} (ignore), or the Scheme procedure which\n"
"handles the signal, or @code{#f} if a non-Scheme procedure handles the\n"
"signal. The CDR contains the current @code{sigaction} flags for the handler.\n\n"
"If @var{handler} is provided, it is installed as the new handler for\n"
"@var{signum}. @var{handler} can be a Scheme procedure taking one\n"
"argument, or the value of @code{SIG_DFL} (default action) or\n"
"@code{SIG_IGN} (ignore), or @code{#f} to restore whatever signal handler\n"
"was installed before @code{sigaction} was first used. When\n"
"a scheme procedure has been specified, that procedure will run\n"
"in the given @var{thread}. When no thread has been given, the\n"
"thread that made this call to @code{sigaction} is used.\n"
"Flags can optionally be specified for the new handler.\n"
"The return value is a pair with information about the\n"
"old handler as described above.\n\n"
"This interface does not provide access to the \"signal blocking\"\n"
"facility. Maybe this is not needed, since the thread support may\n"
"provide solutions to the problem of consistent access to data\n"
"structures.")
#define FUNC_NAME s_scm_sigaction_for_thread
{
int csig;
#ifdef HAVE_SIGACTION
struct sigaction action;
struct sigaction old_action;
#else
SIGRETTYPE (* chandler) (int) = SIG_DFL;
SIGRETTYPE (* old_chandler) (int);
#endif
int query_only = 0;
int save_handler = 0;
SCM old_handler;
csig = scm_to_signed_integer (signum, 0, NSIG-1);
#if defined(HAVE_SIGACTION)
action.sa_flags = 0;
if (!SCM_UNBNDP (flags))
action.sa_flags |= scm_to_int (flags);
sigemptyset (&action.sa_mask);
#endif
if (SCM_UNBNDP (thread))
thread = scm_current_thread ();
else
{
SCM_VALIDATE_THREAD (4, thread);
if (scm_c_thread_exited_p (thread))
SCM_MISC_ERROR ("thread has already exited", SCM_EOL);
}
scm_i_ensure_signal_delivery_thread ();
scm_dynwind_begin (0);
scm_dynwind_pthread_mutex_lock (&signal_handler_lock);
scm_dynwind_block_asyncs ();
old_handler = SCM_SIMPLE_VECTOR_REF (*signal_handlers, csig);
if (SCM_UNBNDP (handler))
query_only = 1;
else if (scm_is_integer (handler))
{
long handler_int = scm_to_long (handler);
if (handler_int == (long) SIG_DFL || handler_int == (long) SIG_IGN)
{
#ifdef HAVE_SIGACTION
action.sa_handler = (SIGRETTYPE (*) (int)) handler_int;
#else
chandler = (SIGRETTYPE (*) (int)) handler_int;
#endif
install_handler (csig, SCM_BOOL_F, SCM_BOOL_F);
}
else
{
SCM_OUT_OF_RANGE (2, handler);
}
}
else if (scm_is_false (handler))
{
/* restore the default handler. */
#ifdef HAVE_SIGACTION
if (orig_handlers[csig].sa_handler == SIG_ERR)
query_only = 1;
else
{
action = orig_handlers[csig];
orig_handlers[csig].sa_handler = SIG_ERR;
install_handler (csig, SCM_BOOL_F, SCM_BOOL_F);
}
#else
if (orig_handlers[csig] == SIG_ERR)
query_only = 1;
else
{
chandler = orig_handlers[csig];
orig_handlers[csig] = SIG_ERR;
install_handler (csig, SCM_BOOL_F, SCM_BOOL_F);
}
#endif
}
else
{
SCM_VALIDATE_PROC (2, handler);
#ifdef HAVE_SIGACTION
action.sa_handler = take_signal;
if (orig_handlers[csig].sa_handler == SIG_ERR)
save_handler = 1;
#else
chandler = take_signal;
if (orig_handlers[csig] == SIG_ERR)
save_handler = 1;
#endif
install_handler (csig, thread, handler);
}
/* XXX - Silently ignore setting handlers for `program error signals'
because they can't currently be handled by Scheme code.
*/
switch (csig)
{
/* This list of program error signals is from the GNU Libc
Reference Manual */
case SIGFPE:
case SIGILL:
case SIGSEGV:
#ifdef SIGBUS
case SIGBUS:
#endif
case SIGABRT:
#if defined(SIGIOT) && (SIGIOT != SIGABRT)
case SIGIOT:
#endif
#ifdef SIGTRAP
case SIGTRAP:
#endif
#ifdef SIGEMT
case SIGEMT:
#endif
#ifdef SIGSYS
case SIGSYS:
#endif
query_only = 1;
}
#ifdef HAVE_SIGACTION
if (query_only)
{
if (sigaction (csig, 0, &old_action) == -1)
SCM_SYSERROR;
}
else
{
if (sigaction (csig, &action , &old_action) == -1)
SCM_SYSERROR;
if (save_handler)
orig_handlers[csig] = old_action;
}
if (old_action.sa_handler == SIG_DFL || old_action.sa_handler == SIG_IGN)
old_handler = scm_from_long ((long) old_action.sa_handler);
scm_dynwind_end ();
return scm_cons (old_handler, scm_from_int (old_action.sa_flags));
#else
if (query_only)
{
if ((old_chandler = signal (csig, SIG_IGN)) == SIG_ERR)
SCM_SYSERROR;
if (signal (csig, old_chandler) == SIG_ERR)
SCM_SYSERROR;
}
else
{
if ((old_chandler = signal (csig, chandler)) == SIG_ERR)
SCM_SYSERROR;
if (save_handler)
orig_handlers[csig] = old_chandler;
}
if (old_chandler == SIG_DFL || old_chandler == SIG_IGN)
old_handler = scm_from_long ((long) old_chandler);
scm_dynwind_end ();
return scm_cons (old_handler, scm_from_int (0));
#endif
}
#undef FUNC_NAME
SCM_DEFINE (scm_restore_signals, "restore-signals", 0, 0, 0,
(void),
"Return all signal handlers to the values they had before any call to\n"
"@code{sigaction} was made. The return value is unspecified.")
#define FUNC_NAME s_scm_restore_signals
{
int i;
for (i = 0; i < NSIG; i++)
{
#ifdef HAVE_SIGACTION
if (orig_handlers[i].sa_handler != SIG_ERR)
{
if (sigaction (i, &orig_handlers[i], NULL) == -1)
SCM_SYSERROR;
orig_handlers[i].sa_handler = SIG_ERR;
SCM_SIMPLE_VECTOR_SET (*signal_handlers, i, SCM_BOOL_F);
}
#else
if (orig_handlers[i] != SIG_ERR)
{
if (signal (i, orig_handlers[i]) == SIG_ERR)
SCM_SYSERROR;
orig_handlers[i] = SIG_ERR;
SCM_SIMPLE_VECTOR_SET (*signal_handlers, i, SCM_BOOL_F);
}
#endif
}
return SCM_UNSPECIFIED;
}
#undef FUNC_NAME
#if HAVE_DECL_ALARM
SCM_DEFINE (scm_alarm, "alarm", 1, 0, 0,
(SCM i),
"Set a timer to raise a @code{SIGALRM} signal after the specified\n"
"number of seconds (an integer). It's advisable to install a signal\n"
"handler for\n"
"@code{SIGALRM} beforehand, since the default action is to terminate\n"
"the process.\n\n"
"The return value indicates the time remaining for the previous alarm,\n"
"if any. The new value replaces the previous alarm. If there was\n"
"no previous alarm, the return value is zero.")
#define FUNC_NAME s_scm_alarm
{
return scm_from_uint (alarm (scm_to_uint (i)));
}
#undef FUNC_NAME
#endif /* HAVE_ALARM */
static void
pack_tv (struct timeval *tv, SCM seconds, SCM microseconds)
{
tv->tv_sec = scm_to_long (seconds);
tv->tv_usec = scm_to_long (microseconds);
/* Allow usec to be outside the range [0, 999999). */
tv->tv_sec += tv->tv_usec / (1000 * 1000);
tv->tv_usec %= 1000 * 1000;
}
static SCM
unpack_tv (const struct timeval *tv)
{
return scm_cons (scm_from_long (tv->tv_sec), scm_from_long (tv->tv_usec));
}
#ifdef HAVE_SETITIMER
SCM_DEFINE (scm_setitimer, "setitimer", 5, 0, 0,
(SCM which_timer,
SCM interval_seconds, SCM interval_microseconds,
SCM value_seconds, SCM value_microseconds),
"Set the timer specified by @var{which_timer} according to the given\n"
"@var{interval_seconds}, @var{interval_microseconds},\n"
"@var{value_seconds}, and @var{value_microseconds} values.\n"
"\n"
"Return information about the timer's previous setting."
"\n"
"Errors are handled as described in the guile info pages under ``POSIX\n"
"Interface Conventions''.\n"
"\n"
"The timers available are: @code{ITIMER_REAL}, @code{ITIMER_VIRTUAL},\n"
"and @code{ITIMER_PROF}.\n"
"\n"
"The return value will be a list of two cons pairs representing the\n"
"current state of the given timer. The first pair is the seconds and\n"
"microseconds of the timer @code{it_interval}, and the second pair is\n"
"the seconds and microseconds of the timer @code{it_value}.")
#define FUNC_NAME s_scm_setitimer
{
int rv;
int c_which_timer;
struct itimerval new_timer;
struct itimerval old_timer;
c_which_timer = SCM_NUM2INT(1, which_timer);
pack_tv (&new_timer.it_interval, interval_seconds, interval_microseconds);
pack_tv (&new_timer.it_value, value_seconds, value_microseconds);
SCM_SYSCALL(rv = setitimer(c_which_timer, &new_timer, &old_timer));
if(rv != 0)
SCM_SYSERROR;
return scm_list_2 (unpack_tv (&old_timer.it_interval),
unpack_tv (&old_timer.it_value));
}
#undef FUNC_NAME
#endif /* HAVE_SETITIMER */
#ifdef HAVE_GETITIMER
SCM_DEFINE (scm_getitimer, "getitimer", 1, 0, 0,
(SCM which_timer),
"Return information about the timer specified by @var{which_timer}"
"\n"
"Errors are handled as described in the guile info pages under ``POSIX\n"
"Interface Conventions''.\n"
"\n"
"The timers available are: @code{ITIMER_REAL}, @code{ITIMER_VIRTUAL},\n"
"and @code{ITIMER_PROF}.\n"
"\n"
"The return value will be a list of two cons pairs representing the\n"
"current state of the given timer. The first pair is the seconds and\n"
"microseconds of the timer @code{it_interval}, and the second pair is\n"
"the seconds and microseconds of the timer @code{it_value}.")
#define FUNC_NAME s_scm_getitimer
{
int rv;
int c_which_timer;
struct itimerval old_timer;
c_which_timer = SCM_NUM2INT(1, which_timer);
SCM_SYSCALL(rv = getitimer(c_which_timer, &old_timer));
if(rv != 0)
SCM_SYSERROR;
return scm_list_2 (scm_cons (scm_from_long (old_timer.it_interval.tv_sec),
scm_from_long (old_timer.it_interval.tv_usec)),
scm_cons (scm_from_long (old_timer.it_value.tv_sec),
scm_from_long (old_timer.it_value.tv_usec)));
}
#undef FUNC_NAME
#endif /* HAVE_GETITIMER */
#ifdef HAVE_PAUSE
SCM_DEFINE (scm_pause, "pause", 0, 0, 0,
(),
"Pause the current process (thread?) until a signal arrives whose\n"
"action is to either terminate the current process or invoke a\n"
"handler procedure. The return value is unspecified.")
#define FUNC_NAME s_scm_pause
{
pause ();
return SCM_UNSPECIFIED;
}
#undef FUNC_NAME
#endif
SCM_DEFINE (scm_sleep, "sleep", 1, 0, 0,
(SCM i),
"Wait for the given number of seconds (an integer) or until a signal\n"
"arrives. The return value is zero if the time elapses or the number\n"
"of seconds remaining otherwise.\n"
"\n"
"See also @code{usleep}.")
#define FUNC_NAME s_scm_sleep
{
return scm_from_uint (scm_std_sleep (scm_to_uint (i)));
}
#undef FUNC_NAME
SCM_DEFINE (scm_usleep, "usleep", 1, 0, 0,
(SCM i),
"Wait the given period @var{usecs} microseconds (an integer).\n"
"If a signal arrives the wait stops and the return value is the\n"
"time remaining, in microseconds. If the period elapses with no\n"
"signal the return is zero.\n"
"\n"
"On most systems the process scheduler is not microsecond accurate and\n"
"the actual period slept by @code{usleep} may be rounded to a system\n"
"clock tick boundary. Traditionally such ticks were 10 milliseconds\n"
"apart, and that interval is often still used.\n"
"\n"
"See also @code{sleep}.")
#define FUNC_NAME s_scm_usleep
{
return scm_from_ulong (scm_std_usleep (scm_to_ulong (i)));
}
#undef FUNC_NAME
SCM_DEFINE (scm_raise, "raise", 1, 0, 0,
(SCM sig),
"Sends a specified signal @var{sig} to the current process, where\n"
"@var{sig} is as described for the kill procedure.")
#define FUNC_NAME s_scm_raise
{
if (raise (scm_to_int (sig)) != 0)
SCM_SYSERROR;
return SCM_UNSPECIFIED;
}
#undef FUNC_NAME
void
scm_i_close_signal_pipe()
{
/* SIGNAL_DELIVERY_THREAD_MUTEX is only locked while the signal delivery
thread is being launched. The thread that calls this function is
already holding the thread admin mutex, so if the delivery thread hasn't
been launched at this point, it never will be before shutdown. */
scm_i_pthread_mutex_lock (&signal_delivery_thread_mutex);
#if SCM_USE_PTHREAD_THREADS
if (scm_i_signal_delivery_thread != NULL)
close (signal_pipe[1]);
#endif
scm_i_pthread_mutex_unlock (&signal_delivery_thread_mutex);
}
void
scm_init_scmsigs ()
{
int i;
signal_handlers =
SCM_VARIABLE_LOC (scm_c_define ("signal-handlers",
scm_c_make_vector (NSIG, SCM_BOOL_F)));
signal_handler_asyncs = scm_c_make_vector (NSIG, SCM_BOOL_F);
signal_handler_threads = scm_c_make_vector (NSIG, SCM_BOOL_F);
for (i = 0; i < NSIG; i++)
{
#ifdef HAVE_SIGACTION
orig_handlers[i].sa_handler = SIG_ERR;
#else
orig_handlers[i] = SIG_ERR;
#endif
}
scm_c_define ("NSIG", scm_from_long (NSIG));
scm_c_define ("SIG_IGN", scm_from_long ((long) SIG_IGN));
scm_c_define ("SIG_DFL", scm_from_long ((long) SIG_DFL));
#ifdef SA_NOCLDSTOP
scm_c_define ("SA_NOCLDSTOP", scm_from_long (SA_NOCLDSTOP));
#endif
#ifdef SA_RESTART
scm_c_define ("SA_RESTART", scm_from_long (SA_RESTART));
#endif
#if defined(HAVE_SETITIMER) || defined(HAVE_GETITIMER)
/* Stuff needed by setitimer and getitimer. */
scm_c_define ("ITIMER_REAL", scm_from_int (ITIMER_REAL));
scm_c_define ("ITIMER_VIRTUAL", scm_from_int (ITIMER_VIRTUAL));
scm_c_define ("ITIMER_PROF", scm_from_int (ITIMER_PROF));
#endif /* defined(HAVE_SETITIMER) || defined(HAVE_GETITIMER) */
#include "libguile/scmsigs.x"
}
/*
Local Variables:
c-file-style: "gnu"
End:
*/
|