From 72da00bf591bf938ccbb71ad519ee5ea938bf128 Mon Sep 17 00:00:00 2001 From: rekado Date: Sat, 29 Dec 2012 20:17:03 +0800 Subject: bypass contacts are wired on the switch, off-board --- gschem/crossover.sch | 84 +++++++++++++++++++++++++++++++++++++++++++--------- 1 file changed, 70 insertions(+), 14 deletions(-) diff --git a/gschem/crossover.sch b/gschem/crossover.sch index d53e01f..26a8a1f 100644 --- a/gschem/crossover.sch +++ b/gschem/crossover.sch @@ -420,7 +420,7 @@ T 53600 46800 5 10 0 1 0 0 1 footprint=RCY100P } N 54500 47000 54900 47000 4 -T 48600 43500 9 10 1 0 0 0 4 +T 48100 43200 9 10 1 0 0 0 4 When the cross-over is disabled, the two send outputs each carry the full signal. S401, S402, S403 are all part of the same @@ -434,13 +434,13 @@ device=none T 45900 46200 5 10 1 1 0 7 1 value=BASS } -C 49700 46100 1 180 0 input-2.sym +C 49800 46100 1 180 0 input-2.sym { -T 49700 45500 5 10 1 0 180 0 1 +T 49800 45500 5 10 1 0 180 0 1 net=XOVER:1 -T 49100 45400 5 10 0 0 180 0 1 +T 49200 45400 5 10 0 0 180 0 1 device=none -T 48500 45700 5 10 1 1 180 7 1 +T 48600 45700 5 10 1 1 180 7 1 value=XOVER } C 47200 46000 1 0 0 switch-spdt-1.sym @@ -449,12 +449,10 @@ T 47600 46800 5 10 0 0 0 0 1 device=SPDT T 47600 46600 5 10 1 1 0 0 1 refdes=S401 -T 47200 46000 5 10 0 0 0 0 1 -footprint=CONNECTOR 3 1 } N 47200 46200 46800 46200 4 N 48100 46400 49800 46400 4 -N 48100 46000 48300 46000 4 +N 48100 46000 48400 46000 4 T 50000 39800 9 10 1 0 0 0 3 This dual pot is wired to blend the two signals. As the resistance of one pot increases, the other @@ -609,8 +607,6 @@ T 52600 47600 5 10 0 0 0 6 1 device=SPDT T 52600 47400 5 10 1 1 0 6 1 refdes=S402 -T 53000 46800 5 10 0 0 0 6 1 -footprint=CONNECTOR 3 1 } C 53000 45300 1 0 1 switch-spdt-1.sym { @@ -618,8 +614,6 @@ T 52600 46100 5 10 0 0 0 6 1 device=SPDT T 52600 45900 5 10 1 1 0 6 1 refdes=S403 -T 53000 45300 5 10 0 0 0 6 1 -footprint=CONNECTOR 3 1 } N 51500 45300 52100 45300 4 N 49800 45700 49800 47200 4 @@ -786,5 +780,67 @@ footprint=R025 N 54800 43100 54800 44200 4 N 54800 44200 55200 44200 4 N 55200 44200 55200 43500 4 -T 47300 47700 9 10 1 0 0 0 1 -TODO: 40{1,2,3}-2 are connected. This can be done off-board. +T 46100 47800 9 10 1 0 0 0 1 +40{1,2,3}-2 are connected at the switch contacts, off-board. +C 53400 47900 1 0 0 connector1-2.sym +{ +T 54100 48800 5 10 1 1 0 6 1 +refdes=CONN420 +T 53700 48750 5 10 0 0 0 0 1 +device=CONNECTOR_1 +T 53700 48950 5 10 0 0 0 0 1 +footprint=CONNECTOR 1 1 +} +C 47000 44600 1 0 0 connector1-2.sym +{ +T 47700 45500 5 10 1 1 0 6 1 +refdes=CONN410 +T 47300 45450 5 10 0 0 0 0 1 +device=CONNECTOR_1 +T 47300 45650 5 10 0 0 0 0 1 +footprint=CONNECTOR 1 1 +} +C 48300 44200 1 0 0 connector1-2.sym +{ +T 49000 45100 5 10 1 1 0 6 1 +refdes=CONN411 +T 48600 45050 5 10 0 0 0 0 1 +device=CONNECTOR_1 +T 48600 45250 5 10 0 0 0 0 1 +footprint=CONNECTOR 1 1 +} +C 51700 47900 1 0 0 connector1-2.sym +{ +T 52400 48800 5 10 1 1 0 6 1 +refdes=CONN421 +T 52000 48750 5 10 0 0 0 0 1 +device=CONNECTOR_1 +T 52000 48950 5 10 0 0 0 0 1 +footprint=CONNECTOR 1 1 +} +C 53400 44400 1 0 0 connector1-2.sym +{ +T 54100 45300 5 10 1 1 0 6 1 +refdes=CONN430 +T 53700 45250 5 10 0 0 0 0 1 +device=CONNECTOR_1 +T 53700 45450 5 10 0 0 0 0 1 +footprint=CONNECTOR 1 1 +} +C 52300 42900 1 0 0 connector1-2.sym +{ +T 53000 43800 5 10 1 1 0 6 1 +refdes=CONN431 +T 52600 43750 5 10 0 0 0 0 1 +device=CONNECTOR_1 +T 52600 43950 5 10 0 0 0 0 1 +footprint=CONNECTOR 1 1 +} +N 53400 48300 53300 48300 4 +N 53300 48300 53300 47000 4 +N 51700 48300 51700 46400 4 +N 48300 46000 48300 44600 4 +N 47000 46200 47000 45000 4 +N 53400 44800 53200 44800 4 +N 52300 43300 51800 43300 4 +N 51800 43300 51800 45300 4 -- cgit v1.2.3